Featured
-
China wholesale Turbomolecular Pump Vacuum Range - Resistance Vacuum Gauge, ZDR-12/06B, 1E-1 to 1E-8 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDR-12/06B vacuum gauge can achieve continuous measurement and control for 1*E-1~1*E-8Pa, and have analog signal output( 0-5V). Interface RS485. This ZDR-12/06B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDR-12/06B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability ( preferred for R&D and industrial production) Specifications: ... -
PriceList for Vacuum Vanes - Compound Vacuum Gauge, ZDF-62B5, 10E5 to 10E-7 Pa, 6 loops, Rs485 – KYKY
Model ZDF-62B5 compound vacuum gauge is composed of 2 sets of low vacuum measuring units and 1 set of high vacuum measuring units. One unit of resistance gauge (RG 2)is used to achieve the measurement (1.0×10E5Pa~1.0×10E-7Pa)independently, the unit of resistance gauge( RG1) combined with ionization gauge, as compound unit, is to achieve the continuous control and measurement (1×10E5~1×10E-7Pa). Advantages: 1. Manual or automatic mode. 2. Convenient and flexible control 3. Long up-time, stab... -
Good quality Hydraulic Pump Pressure Gauge - Turbo Molecular Pump, FF-100/110E, Air cooling, Grease lubrication, 110L/s N2 – KYKY
The grease-lubrication pump is equipped with ceramic bearing, which is usually of a self-sealed structure, consisting of a bearing inner ring, a bearing outer ring, balls, holders, a sealing end cover and lubricating grease. Shafting support structure applied to the grease-lubricated ceramic bearing has advantages of simple structure, free maintenance and low power consumption, so that molecular pump products can be installed in any orientation, and only need to be maintained once every 3-5 y... -
Cheap PriceList for Two Stage Rotary Vane Pump - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:... -
Renewable Design for Electric Vacuum Pump For Power Brake Booster - Resistance Vacuum Gauge, ZDR-12/06B, 1E-1 to 1E-8 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDR-12/06B vacuum gauge can achieve continuous measurement and control for 1*E-1~1*E-8Pa, and have analog signal output( 0-5V). Interface RS485. This ZDR-12/06B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDR-12/06B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability ( preferred for R&D and industrial production) Specifications: ... -
Bottom price Helium Leak Detection System - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:... -
2021 Good Quality Pneumatic Gate Valve - Gate Valve,Pneumatic Drive,CCQseries DN35-400 – KYKY
Model CCQ-35B CCQ-50B CCQ-63B CCQ-80A CCQ-100A CCQ-150A CCQ-200A CCQ-250A CCQ-320B CCQ-400B Flange ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF nominal Diameter DN35 DN50 DN63 DN80 DN100 DN150 DN200 DN250 DN320 DN400 (Pa) range of application 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10... -
2021 Good Quality Helium Gas Leak Detector - Helium Leak Detector ZQJ-2000 Max inlet pressure 1000Pa Detectabel leak rate2*E-11 Pa*m3/s – KYKY
With nearly 50 years of vacuum leak detection technology experience, KYKY is the largest R&D and production base of HLD and has the independent intellectual property rights for vacuum leak detection system. The leak detectors and leak detection systems developed by KYKY provide advanced and effective leak detection solutions to aerospace, power electronics, air conditioning refrigeration, chemical metallurgy, medical equipment, semiconductor production and many other applications to meet ... -
Factory Supply Gate Valve Valve - Gate Valve, Manual Drive, CC series DN35-400 – KYKY
Model CC-35B CC-50B CC-63B CC-80A CC-100A/p> CC-150A CC-200A CC-250A CC-320B CC-400B Flange CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K nominal Diameter DN35 DN50 DN63 DN80 DN100 DN150 DN200 DN250 DN320 DN400 range of application(Pa) 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 ... -
OEM Manufacturer automatic grease pump - Compound Vacuum Gauge, ZDF-62B5, 10E5 to 10E-7 Pa, 6 loops, Rs485 – KYKY
Model ZDF-62B5 compound vacuum gauge is composed of 2 sets of low vacuum measuring units and 1 set of high vacuum measuring units. One unit of resistance gauge (RG 2)is used to achieve the measurement (1.0×10E5Pa~1.0×10E-7Pa)independently, the unit of resistance gauge( RG1) combined with ionization gauge, as compound unit, is to achieve the continuous control and measurement (1×10E5~1×10E-7Pa). Advantages: 1. Manual or automatic mode. 2. Convenient and flexible control 3. Long up-time, stab... -
Professional China Electric driven gate valve - Gate Valve, Manual Drive, CC series DN35-400 – KYKY
Model CC-35B CC-50B CC-63B CC-80A CC-100A/p> CC-150A CC-200A CC-250A CC-320B CC-400B Flange CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K nominal Diameter DN35 DN50 DN63 DN80 DN100 DN150 DN200 DN250 DN320 DN400 range of application(Pa) 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 ... -
Bottom price Gauge - Turbo Molecular Pump, F-400/3500B, Water cooling, Oil lubrication – KYKY
Advantages: This series of pump is good at performance under harsh environmental (high temperature, dust, etc.), stable in performance and with long service life, and simple maintenance and convenient operation as well. Applications: Main applications are in industrial leak detection, PVD, CVD, ion implantation, vacuum electronic components manufacturing, low-E glass, ITO glass, optical coating, solar cells, electron beam welding, vacuum furnace and other industries Specifications: Flang...
