Featured
-
Factory directly Rotary Vane pump - Resistance Vacuum Gauge, ZDR-12/06B, 1E-1 to 1E-8 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDR-12/06B vacuum gauge can achieve continuous measurement and control for 1*E-1~1*E-8Pa, and have analog signal output( 0-5V). Interface RS485. This ZDR-12/06B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDR-12/06B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability ( preferred for R&D and industrial production) Specifications: ... -
Chinese wholesale Rotary Vane Primer Pump - Compound Vacuum Gauge, ZDF-62B5, 10E5 to 10E-7 Pa, 6 loops, Rs485 – KYKY
Model ZDF-62B5 compound vacuum gauge is composed of 2 sets of low vacuum measuring units and 1 set of high vacuum measuring units. One unit of resistance gauge (RG 2)is used to achieve the measurement (1.0×10E5Pa~1.0×10E-7Pa)independently, the unit of resistance gauge( RG1) combined with ionization gauge, as compound unit, is to achieve the continuous control and measurement (1×10E5~1×10E-7Pa). Advantages: 1. Manual or automatic mode. 2. Convenient and flexible control 3. Long up-time, stab... -
High definition And Gate Valve - Gate Valve, Electric Drive, CCD series DN35-400 – KYKY
Model CCD-35B CCD-50B CCD-63B CCD-80A CCD-100A CCD-150A CCD-200A CCD-250A CCD-320B CCD-400B Flange CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K nominal Diameter DN35 DN50 DN63 DN80 DN100 DN150 DN200 DN250 DN320 DN400 (Pa) range of application 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 ... -
2021 High quality Gate Valve Types - Gate Valve,Pneumatic Drive,CCQseries DN35-400 – KYKY
Model CCQ-35B CCQ-50B CCQ-63B CCQ-80A CCQ-100A CCQ-150A CCQ-200A CCQ-250A CCQ-320B CCQ-400B Flange ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF nominal Diameter DN35 DN50 DN63 DN80 DN100 DN150 DN200 DN250 DN320 DN400 (Pa) range of application 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10... -
One of Hottest for Principle of Rotary Vane pump - Compound Vacuum Gauge, ZDF-11B5, 10E5 to 10E-5 Pa, Rs-485(Modbus-RTU) – KYKY
Advantages: The ZDF-11B5 can be set in manual or automatic mode according to the actual operation requirements. This type of vacuum gauge, with advantages of convenient and flexible control, long up-time, stability, reliability and strong anti-jam capability, In the R&D and industrial production field, this type of vacuum gauge has a good preference. Specifications: Compound vacuum gauge ZDF-11B5 Measured loop 2,(Resistance gauge and ionization gauge each) Type of gauge ZJ-52T re... -
Cheap price Becker Vacuum Pump Manual - Compound Vacuum Gauge, ZDF-62B5, 10E5 to 10E-7 Pa, 6 loops, Rs485 – KYKY
Model ZDF-62B5 compound vacuum gauge is composed of 2 sets of low vacuum measuring units and 1 set of high vacuum measuring units. One unit of resistance gauge (RG 2)is used to achieve the measurement (1.0×10E5Pa~1.0×10E-7Pa)independently, the unit of resistance gauge( RG1) combined with ionization gauge, as compound unit, is to achieve the continuous control and measurement (1×10E5~1×10E-7Pa). Advantages: 1. Manual or automatic mode. 2. Convenient and flexible control 3. Long up-time, stab... -
OEM/ODM Factory Small Vacuum Pump - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:... -
2021 wholesale price Rotary Vane Drum Pump - Compound Vacuum Gauge, ZDF-62B5, 10E5 to 10E-7 Pa, 6 loops, Rs485 – KYKY
Model ZDF-62B5 compound vacuum gauge is composed of 2 sets of low vacuum measuring units and 1 set of high vacuum measuring units. One unit of resistance gauge (RG 2)is used to achieve the measurement (1.0×10E5Pa~1.0×10E-7Pa)independently, the unit of resistance gauge( RG1) combined with ionization gauge, as compound unit, is to achieve the continuous control and measurement (1×10E5~1×10E-7Pa). Advantages: 1. Manual or automatic mode. 2. Convenient and flexible control 3. Long up-time, stab... -
Popular Design for Vacuum Pump Controller - Compound Vacuum Gauge, ZDF-11B5, 10E5 to 10E-5 Pa, Rs-485(Modbus-RTU) – KYKY
Advantages: The ZDF-11B5 can be set in manual or automatic mode according to the actual operation requirements. This type of vacuum gauge, with advantages of convenient and flexible control, long up-time, stability, reliability and strong anti-jam capability, In the R&D and industrial production field, this type of vacuum gauge has a good preference. Specifications: Compound vacuum gauge ZDF-11B5 Measured loop 2,(Resistance gauge and ionization gauge each) Type of gauge ZJ-52T re... -
Fast delivery Helium Detection Equipment - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:... -
Discount Price Vacuum Pump Oil Mist - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:... -
Chinese wholesale Turbo Pumping Station - Pump station FJ-80, Compact oil or dry backup pump optional – KYKY
Flange(In) CF 63CF recommended forevacuum pressure Pa <50 forevacuum pump GHD-031B(oil)( dry pump optional) Flange(Out) ISO-KF DN25 Cooling Type,Standard Air Pumping Speed l/s N2:62 He:55 H2:34 Input voltage/ frequency V/Hz 220±22/50 Ar:65 Environment temperature (℃) Air cooling 5℃-32℃ Compression Ratio N2:109 He:105 mounting position Vertical H2:104 Controller Model TCP-100 Ar:109 L*W*H mm 400×300×260 Ultimate Pressure Pa CF:5×10...
