Featured
-
China wholesale Turbomolecular Pump Vacuum Range - Compound Vacuum Gauge, ZDF-62B5, 10E5 to 10E-7 Pa, 6 loops, Rs485 – KYKY
Model ZDF-62B5 compound vacuum gauge is composed of 2 sets of low vacuum measuring units and 1 set of high vacuum measuring units. One unit of resistance gauge (RG 2)is used to achieve the measurement (1.0×10E5Pa~1.0×10E-7Pa)independently, the unit of resistance gauge( RG1) combined with ionization gauge, as compound unit, is to achieve the continuous control and measurement (1×10E5~1×10E-7Pa). Advantages: 1. Manual or automatic mode. 2. Convenient and flexible control 3. Long up-time, stab... -
Manufacturer of Air Operated Vacuum Pump - Compound Vacuum Gauge, ZDF-62B5, 10E5 to 10E-7 Pa, 6 loops, Rs485 – KYKY
Model ZDF-62B5 compound vacuum gauge is composed of 2 sets of low vacuum measuring units and 1 set of high vacuum measuring units. One unit of resistance gauge (RG 2)is used to achieve the measurement (1.0×10E5Pa~1.0×10E-7Pa)independently, the unit of resistance gauge( RG1) combined with ionization gauge, as compound unit, is to achieve the continuous control and measurement (1×10E5~1×10E-7Pa). Advantages: 1. Manual or automatic mode. 2. Convenient and flexible control 3. Long up-time, stab... -
2021 High quality Oil Sealed Rotary Vacuum Pump - Compound Vacuum Gauge, ZDF-11B5, 10E5 to 10E-5 Pa, Rs-485(Modbus-RTU) – KYKY
Advantages: The ZDF-11B5 can be set in manual or automatic mode according to the actual operation requirements. This type of vacuum gauge, with advantages of convenient and flexible control, long up-time, stability, reliability and strong anti-jam capability, In the R&D and industrial production field, this type of vacuum gauge has a good preference. Specifications: Compound vacuum gauge ZDF-11B5 Measured loop 2,(Resistance gauge and ionization gauge each) Type of gauge ZJ-52T re... -
Bottom price Gauge - Turbo Molecular Pump, FF-63/80E with integrated Drive module, Water/Air cooling, Grease lubrication – KYKY
Flange(In) ISO-K/CF63 Max. Fore-vacuum Pressure N2:1500 Flange(Out) KF DN16 Gas Throughout (sccm) N2:35 Pumping Speed( L/s) N2:63-80 He:30 He:55 H2:19 H2:34 Ar:38 Ar:65 Rotation Speed ( rpm) 72000 Compression Ratio N2:109 Run-Up Time(min) ≤2 He:105 Cooling Type,Standard Water or Air H2:104 Cooling Water Consumption ( L/min) 1 Ar:109 Cooling Water Temperature(℃) ≤25 Ultimated Pressure(Pa) CF:5×10-6 Power Connection:Voltage (V AC) DC24/AC2... -
2021 wholesale price Gate Valve Parts - Gate Valve,Pneumatic Drive,CCQseries DN35-400 – KYKY
Model CCQ-35B CCQ-50B CCQ-63B CCQ-80A CCQ-100A CCQ-150A CCQ-200A CCQ-250A CCQ-320B CCQ-400B Flange ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF ISO-K/ F, CF nominal Diameter DN35 DN50 DN63 DN80 DN100 DN150 DN200 DN250 DN320 DN400 (Pa) range of application 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10... -
Manufacturer for Helium Vacuum Leak Detector - Helium Leak Detector, ZQJ-3200, Min rate 5*1E-13, Display 5E-13 to 1E-1 – KYKY
The ZQJ-3200 Helium Leak Detectors are microprocessor-controller leak detecting instruments. All the processes in the instrument are controlled automatically. Advanteges: 1. Easy operation–Small volume, light weight, compact structure, remote operation panel 2. Multiful interface–Rs232, Digital I/O, USD port 3. Powerful functions–Various test mode, capability of detecting H2. 3He, amd 4He, multiple menu setting 4. Reliable performance–High sensitivity, wide measurement... -
Factory source pump grease manual - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:... -
Excellent quality Helium Leak Checker - Resistance Vacuum Gauge, ZDR-12/06B, 1E-1 to 1E-8 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDR-12/06B vacuum gauge can achieve continuous measurement and control for 1*E-1~1*E-8Pa, and have analog signal output( 0-5V). Interface RS485. This ZDR-12/06B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDR-12/06B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability ( preferred for R&D and industrial production) Specifications: ... -
Good quality Gate Valve Is - Gate Valve, Electric Drive, CCD series DN35-400 – KYKY
Model CCD-35B CCD-50B CCD-63B CCD-80A CCD-100A CCD-150A CCD-200A CCD-250A CCD-320B CCD-400B Flange CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K CF/ISO-F/ISO-K nominal Diameter DN35 DN50 DN63 DN80 DN100 DN150 DN200 DN250 DN320 DN400 (Pa) range of application 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 105 —10-7 ... -
Wholesale Helium Gas Detector - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:... -
Hot sale Factory Turbomolecular Pump Pressure Range - Resistance Vacuum Gauge, ZDR-12/06B, 1E-1 to 1E-8 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDR-12/06B vacuum gauge can achieve continuous measurement and control for 1*E-1~1*E-8Pa, and have analog signal output( 0-5V). Interface RS485. This ZDR-12/06B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDR-12/06B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability ( preferred for R&D and industrial production) Specifications: ... -
New Fashion Design for Rotary Vane pump selection - Resistance Vacuum Gauge, ZDZ-52T/07B, 1E5 to 1E-1 Pa, Analog signal, 0-5V, Rs485 – KYKY
Model ZDZ-52T/07B vacuum gauge can achieve continuous measurement and control for 1*E5~1*E-1Pa, and have analog signal output( 0-5V). Interface RS485. This ZDZ-52T/07B, has 1 measure loop and 2 control loops, the control accuracy can reach ±1%. ZDZ-52T/07B is panel amount type with standard amounting dimensions. Advantages: 1. convenient and flexible control 2. Long up-time, stability, reliability 3. Strong anti-jam capability (preferred for R&D and industrial production) Specifications:...